000141562 245__ $$aAssessment of the technical usability and efficacy of a new portable dry-electrode EEG recorder: First results of the HOMEONE study.
000141562 260__ $$aAmsterdam [u.a.]$$bElsevier Science$$c2019
000141562 264_1 $$2Crossref$$3print$$bElsevier BV$$c2019-11-01
000141562 3367_ $$2DRIVER$$aarticle
000141562 3367_ $$2DataCite$$aOutput Types/Journal article
000141562 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1705668195_6327
000141562 3367_ $$2BibTeX$$aARTICLE
000141562 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000141562 3367_ $$00$$2EndNote$$aJournal Article
000141562 520__ $$aThe HOME project is intended to provide evidence of diagnostic and therapeutic yield of a patient-controlled EEG home-monitoring for neurological outpatients.This study evaluated the technical and practical usability and efficacy of a new portable dry-electrode EEG recorder in comparison to conventional EEG devices based on technical assessments and inter-rater comparisons of EEG record examinations of office-based practitioners and two experienced neurologists.The technical assessment was based on channel-wise comparisons of band power values derived from power spectra as observed in two recording modalities. Slight yet significant differences were observed only in the Delta-frequency band (1.5-4 Hz). The fraction of automatically detected artifact segments was larger in the new portable recordings than in conventional recordings (20% vs. 11%, median). Overall, 93% of raters' stated diagnostic findings gathered from conventional devices were concordant with stated diagnostic findings gathered from the new portable device.The new EEG device was shown to have technical comparability to and a high concordance rate of diagnostic findings with conventional EEG devices.The new portable dry-electrode EEG device is suitable to meet the HOME projects' goal of establishing a patient-controlled EEG home-monitoring in the routine care of neurological outpatients.DRKS DRKS00012685. Registered 09 August 2017, retrospectively registered.
000141562 536__ $$0G:(DE-HGF)POF3-344$$a344 - Clinical and Health Care Research (POF3-344)$$cPOF3-344$$fPOF III$$x0
000141562 542__ $$2Crossref$$i2019-11-01$$uhttps://www.elsevier.com/tdm/userlicense/1.0/
000141562 588__ $$aDataset connected to CrossRef, PubMed,
000141562 650_2 $$2MeSH$$aBrain: physiopathology
000141562 650_2 $$2MeSH$$aElectroencephalography: instrumentation
000141562 650_2 $$2MeSH$$aElectroencephalography: methods
000141562 650_2 $$2MeSH$$aHumans
000141562 650_2 $$2MeSH$$aMonitoring, Physiologic
000141562 650_2 $$2MeSH$$aNervous System Diseases: physiopathology
000141562 650_2 $$2MeSH$$aSelf-Management
000141562 7001_ $$aBaum, Anne Katrin$$b1
000141562 7001_ $$aBaum, Ulrike$$b2
000141562 7001_ $$aDeike, Renate$$b3
000141562 7001_ $$aFeistner, Helmut$$b4
000141562 7001_ $$aScholz, Michael$$b5
000141562 7001_ $$0P:(DE-2719)2000009$$aHinrichs, Hermann$$b6$$udzne
000141562 7001_ $$aRobra, Bernt-Peter$$b7
000141562 77318 $$2Crossref$$3journal-article$$a10.1016/j.clinph.2019.08.012$$b : Elsevier BV, 2019-11-01$$n11$$p2076-2087$$tClinical Neurophysiology$$v130$$x1388-2457$$y2019
000141562 773__ $$0PERI:(DE-600)1499934-1$$a10.1016/j.clinph.2019.08.012$$gVol. 130, no. 11, p. 2076 - 2087$$n11$$p2076-2087$$q130:11<2076 - 2087$$tClinical neurophysiology$$v130$$x1388-2457$$y2019
000141562 8564_ $$uhttps://pub.dzne.de/record/141562/files/DZNE-2020-07886_Restricted.pdf
000141562 8564_ $$uhttps://pub.dzne.de/record/141562/files/DZNE-2020-07886_Restricted.pdf?subformat=pdfa$$xpdfa
000141562 909CO $$ooai:pub.dzne.de:141562$$pVDB
000141562 9101_ $$0I:(DE-588)1065079516$$6P:(DE-2719)2000009$$aDeutsches Zentrum für Neurodegenerative Erkrankungen$$b6$$kDZNE
000141562 9131_ $$0G:(DE-HGF)POF3-344$$1G:(DE-HGF)POF3-340$$2G:(DE-HGF)POF3-300$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bGesundheit$$lErkrankungen des Nervensystems$$vClinical and Health Care Research$$x0
000141562 9141_ $$y2019
000141562 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2022-11-05$$wger
000141562 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bCLIN NEUROPHYSIOL : 2021$$d2022-11-05
000141562 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2022-11-05
000141562 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2022-11-05
000141562 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2022-11-05
000141562 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2022-11-05
000141562 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2022-11-05
000141562 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2022-11-05
000141562 915__ $$0StatID:(DE-HGF)1050$$2StatID$$aDBCoverage$$bBIOSIS Previews$$d2022-11-05
000141562 915__ $$0StatID:(DE-HGF)1030$$2StatID$$aDBCoverage$$bCurrent Contents - Life Sciences$$d2022-11-05
000141562 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2022-11-05
000141562 9201_ $$0I:(DE-2719)7000000$$kU Clinical Researchers - Magdeburg$$lU Clinical Researchers - Magdeburg$$x0
000141562 980__ $$ajournal
000141562 980__ $$aVDB
000141562 980__ $$aI:(DE-2719)7000000
000141562 980__ $$aUNRESTRICTED