| Home > In process > Motion- and Field-Robust Mesoscopic Whole-Brain T 2 * $$ {T}_2^{\ast } $$ -Weighted Imaging at 7 and 11.7 T Using Servo Navigation. > print |
| 001 | 285473 | ||
| 005 | 20260309094148.0 | ||
| 024 | 7 | _ | |a 10.1002/mrm.70251 |2 doi |
| 024 | 7 | _ | |a pmid:41527210 |2 pmid |
| 024 | 7 | _ | |a pmc:PMC12962216 |2 pmc |
| 024 | 7 | _ | |a 1522-2594 |2 ISSN |
| 024 | 7 | _ | |a 0740-3194 |2 ISSN |
| 037 | _ | _ | |a DZNE-2026-00250 |
| 041 | _ | _ | |a English |
| 082 | _ | _ | |a 610 |
| 100 | 1 | _ | |a Serger, Matthias |0 P:(DE-2719)9001410 |b 0 |e First author |
| 245 | _ | _ | |a Motion- and Field-Robust Mesoscopic Whole-Brain T 2 * $$ {T}_2^{\ast } $$ -Weighted Imaging at 7 and 11.7 T Using Servo Navigation. |
| 260 | _ | _ | |a New York, NY [u.a.] |c 2026 |b Wiley-Liss |
| 336 | 7 | _ | |a article |2 DRIVER |
| 336 | 7 | _ | |a Output Types/Journal article |2 DataCite |
| 336 | 7 | _ | |a Journal Article |b journal |m journal |0 PUB:(DE-HGF)16 |s 1773045590_14564 |2 PUB:(DE-HGF) |
| 336 | 7 | _ | |a ARTICLE |2 BibTeX |
| 336 | 7 | _ | |a JOURNAL_ARTICLE |2 ORCID |
| 336 | 7 | _ | |a Journal Article |0 0 |2 EndNote |
| 520 | _ | _ | |a To mitigate artifacts related to motion and field changes in high-resolution T 2 * $$ {T}_2^{\ast } $$ -weighted human brain imaging using servo navigation at ultra-high fields up to 11.7 T.MR-based servo navigators were integrated into a segmented 3D-EPI sequence to allow for prospective correction of involuntary head motion and first-order shim changes. Seven subjects were scanned with whole-brain protocols at 0.3 mm isotropic resolution with and without correction at 7 and 11.7 T. Validation was performed on detailed brain vasculature in scans with involuntary motion.Blurring of small veins was reduced by servo navigation for all subjects and across field strengths. In case of involuntary large motion, the method preserved image quality, while uncorrected motion led to severe artifacts. In case of microscopic motion, reduced blurring and shading in the frontal lobe demonstrate the additional benefit of prospective field drift correction.Servo-navigated segmented 3D-EPI improves 0.3 mm isotropic whole-brain T 2 * $$ {T}_2^{\ast } $$ -weighted imaging under realistic motion and field changes within 5.5 to 11 min scan time at 11.7 and 7 T. |
| 536 | _ | _ | |a 354 - Disease Prevention and Healthy Aging (POF4-354) |0 G:(DE-HGF)POF4-354 |c POF4-354 |f POF IV |x 0 |
| 588 | _ | _ | |a Dataset connected to CrossRef, PubMed, , Journals: pub.dzne.de |
| 650 | _ | 7 | |a 11.7 T |2 Other |
| 650 | _ | 7 | |a 3D‐EPI |2 Other |
| 650 | _ | 7 | |a brain vasculature |2 Other |
| 650 | _ | 7 | |a mesoscopic imaging |2 Other |
| 650 | _ | 7 | |a prospective motion correction |2 Other |
| 650 | _ | 7 | |a servo navigation |2 Other |
| 650 | _ | 2 | |a Humans |2 MeSH |
| 650 | _ | 2 | |a Brain: diagnostic imaging |2 MeSH |
| 650 | _ | 2 | |a Artifacts |2 MeSH |
| 650 | _ | 2 | |a Imaging, Three-Dimensional: methods |2 MeSH |
| 650 | _ | 2 | |a Motion |2 MeSH |
| 650 | _ | 2 | |a Male |2 MeSH |
| 650 | _ | 2 | |a Adult |2 MeSH |
| 650 | _ | 2 | |a Female |2 MeSH |
| 650 | _ | 2 | |a Echo-Planar Imaging: methods |2 MeSH |
| 650 | _ | 2 | |a Algorithms |2 MeSH |
| 650 | _ | 2 | |a Image Processing, Computer-Assisted: methods |2 MeSH |
| 650 | _ | 2 | |a Magnetic Resonance Imaging: methods |2 MeSH |
| 650 | _ | 2 | |a Reproducibility of Results |2 MeSH |
| 700 | 1 | _ | |a Stirnberg, Rüdiger |0 P:(DE-2719)2810697 |b 1 |
| 700 | 1 | _ | |a Ehses, Philipp |0 P:(DE-2719)2812222 |b 2 |
| 700 | 1 | _ | |a Riedel, Malte |0 0000-0002-5703-7408 |b 3 |
| 700 | 1 | _ | |a Ulrich, Thomas |0 0000-0003-1811-4295 |b 4 |
| 700 | 1 | _ | |a Le Ster, Caroline |0 0000-0002-4767-8738 |b 5 |
| 700 | 1 | _ | |a Mauconduit, Franck |0 P:(DE-2719)9002043 |b 6 |
| 700 | 1 | _ | |a Gras, Vincent |0 0000-0002-4997-2738 |b 7 |
| 700 | 1 | _ | |a Amadon, Alexis |0 0000-0002-2667-9387 |b 8 |
| 700 | 1 | _ | |a Vignaud, Alexandre |0 0000-0001-9203-0247 |b 9 |
| 700 | 1 | _ | |a Chu, Son |0 0000-0002-4170-777X |b 10 |
| 700 | 1 | _ | |a Gunamony, Shajan |0 0000-0002-3146-6079 |b 11 |
| 700 | 1 | _ | |a Zaitsev, Maxim |0 0000-0001-7530-1228 |b 12 |
| 700 | 1 | _ | |a Boulant, Nicolas |0 0000-0003-2144-2484 |b 13 |
| 700 | 1 | _ | |a Pruessmann, Klaas P |0 0000-0003-0009-8362 |b 14 |
| 700 | 1 | _ | |a Stoecker, Tony |0 P:(DE-2719)2810538 |b 15 |e Last author |
| 773 | _ | _ | |a 10.1002/mrm.70251 |g Vol. 95, no. 5, p. 2658 - 2670 |0 PERI:(DE-600)1493786-4 |n 5 |p 2658 - 2670 |t Magnetic resonance in medicine |v 95 |y 2026 |x 1522-2594 |
| 856 | 4 | _ | |u https://pub.dzne.de/record/285473/files/DZNE-2026-00250.pdf |y Restricted |
| 856 | 4 | _ | |u https://pub.dzne.de/record/285473/files/DZNE-2026-00250.pdf?subformat=pdfa |x pdfa |y Restricted |
| 910 | 1 | _ | |a Deutsches Zentrum für Neurodegenerative Erkrankungen |0 I:(DE-588)1065079516 |k DZNE |b 0 |6 P:(DE-2719)9001410 |
| 910 | 1 | _ | |a Deutsches Zentrum für Neurodegenerative Erkrankungen |0 I:(DE-588)1065079516 |k DZNE |b 1 |6 P:(DE-2719)2810697 |
| 910 | 1 | _ | |a Deutsches Zentrum für Neurodegenerative Erkrankungen |0 I:(DE-588)1065079516 |k DZNE |b 2 |6 P:(DE-2719)2812222 |
| 910 | 1 | _ | |a Deutsches Zentrum für Neurodegenerative Erkrankungen |0 I:(DE-588)1065079516 |k DZNE |b 15 |6 P:(DE-2719)2810538 |
| 913 | 1 | _ | |a DE-HGF |b Gesundheit |l Neurodegenerative Diseases |1 G:(DE-HGF)POF4-350 |0 G:(DE-HGF)POF4-354 |3 G:(DE-HGF)POF4 |2 G:(DE-HGF)POF4-300 |4 G:(DE-HGF)POF |v Disease Prevention and Healthy Aging |x 0 |
| 915 | _ | _ | |a Nationallizenz |0 StatID:(DE-HGF)0420 |2 StatID |d 2025-11-11 |w ger |
| 915 | _ | _ | |a DEAL Wiley |0 StatID:(DE-HGF)3001 |2 StatID |d 2025-11-11 |w ger |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0200 |2 StatID |b SCOPUS |d 2025-11-11 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0300 |2 StatID |b Medline |d 2025-11-11 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0199 |2 StatID |b Clarivate Analytics Master Journal List |d 2025-11-11 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1110 |2 StatID |b Current Contents - Clinical Medicine |d 2025-11-11 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1190 |2 StatID |b Biological Abstracts |d 2025-11-11 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0160 |2 StatID |b Essential Science Indicators |d 2025-11-11 |
| 915 | _ | _ | |a WoS |0 StatID:(DE-HGF)0113 |2 StatID |b Science Citation Index Expanded |d 2025-11-11 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)0150 |2 StatID |b Web of Science Core Collection |d 2025-11-11 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1030 |2 StatID |b Current Contents - Life Sciences |d 2025-11-11 |
| 915 | _ | _ | |a DBCoverage |0 StatID:(DE-HGF)1050 |2 StatID |b BIOSIS Previews |d 2025-11-11 |
| 915 | _ | _ | |a JCR |0 StatID:(DE-HGF)0100 |2 StatID |b MAGN RESON MED : 2022 |d 2025-11-11 |
| 915 | _ | _ | |a IF < 5 |0 StatID:(DE-HGF)9900 |2 StatID |d 2025-11-11 |
| 920 | 1 | _ | |0 I:(DE-2719)1013026 |k AG Stöcker |l MR Physics |x 0 |
| 980 | _ | _ | |a journal |
| 980 | _ | _ | |a EDITORS |
| 980 | _ | _ | |a VDBINPRINT |
| 980 | _ | _ | |a I:(DE-2719)1013026 |
| 980 | _ | _ | |a UNRESTRICTED |
| Library | Collection | CLSMajor | CLSMinor | Language | Author |
|---|