Journal Article DZNE-2024-01295

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Spiral 3DREAM sequence for fast whole‐brain B1 mapping

 ;  ;  ;

2025
Wiley-Liss New York, NY [u.a.]

Magnetic resonance in medicine 93(1), 321 - 329 () [10.1002/mrm.30282]

This record in other databases:  

Please use a persistent id in citations: doi:

Abstract: This work demonstrates a new variant of the 3DREAM sequence for whole-brain B 1 + $$ {\mathrm{B}}_1^{+} $$ mapping employing a three-dimensional (3D) stack-of-spirals readout. The spiral readout reduces the echo train length after the STEAM preparation in order to overcome the significant blurring in STE* images due to the decreasing STE* signal with each excitation pulse.The 3DREAM sequence rapidly acquires two contrasts to calculate whole-brain flip angle maps. In the proposed spiral 3DREAM sequence, the Cartesian readout scheme is replaced by an accelerated 3D stack-of-spirals readout with a CAIPIRINHA sampling scheme. Phantom experiments were conducted to compare flip angle maps of the spiral 3DREAM sequence to a Cartesian 3DREAM sequence, an actual flip-angle-imaging (AFI) sequence, the dual-angle method, and the Bloch-Siegert shift method. Afterwards, the results were validated in vivo acquiring flip angle maps from five subjects.Flip angle maps of the spiral 3DREAM sequences showed high agreement with the reference methods both in phantom and in vivo experiments. Blurring in STE* images and flip angle maps was reduced compared to the Cartesian 3DREAM sequence.The spiral 3DREAM sequence utilizes a fast readout minimizing the echo train length of the imaging train. This reduces blurring in STE* images as well as the total acquisition time and increases the effective resolution of B 1 + $$ {\mathrm{B}}_1^{+} $$ maps.

Keyword(s): Humans (MeSH) ; Imaging, Three-Dimensional: methods (MeSH) ; Brain: diagnostic imaging (MeSH) ; Phantoms, Imaging (MeSH) ; Algorithms (MeSH) ; Magnetic Resonance Imaging: methods (MeSH) ; Reproducibility of Results (MeSH) ; Brain Mapping: methods (MeSH) ; Image Interpretation, Computer-Assisted: methods (MeSH) ; Image Enhancement: methods (MeSH)

Classification:

Contributing Institute(s):
  1. MR Physics (AG Stöcker)
  2. Artificial Intelligence in Medicine (AG Reuter)
Research Program(s):
  1. 354 - Disease Prevention and Healthy Aging (POF4-354) (POF4-354)

Appears in the scientific report 2024
Database coverage:
Medline ; Creative Commons Attribution-NonCommercial CC BY-NC 4.0 ; OpenAccess ; BIOSIS Previews ; Biological Abstracts ; Clarivate Analytics Master Journal List ; Current Contents - Clinical Medicine ; Current Contents - Life Sciences ; DEAL Wiley ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Institute Collections > BN DZNE > BN DZNE-AG Stöcker
Institute Collections > BN DZNE > BN DZNE-AG Reuter
Full Text Collection
Public records
Publications Database


Linked articles:

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Software
Software: Spiral 3DREAM, v1
Zenodo () [10.5281/ZENODO.8319271] BibTeX | EndNote: XML, Text | RIS


 Record created 2024-10-30, last modified 2025-01-27


OpenAccess:
Download fulltext PDF Download fulltext PDF (PDFA)
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)